Part Number Hot Search : 
MBT22 SCN2674T 406C34 LV5781 FXT449SM JRC455 C0603X A5800952
Product Description
Full Text Search
 

To Download RA100Z Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  agency listings 400 series plug-in thermal detectors system sensor 400 series plug-in thermal detectors meet the performance criteria designated by underwriters laboratories. features ? low standby current ? two visible leds blink in standby and provide a 360 field viewing angle ? wide variety of mounting bases with built-in shorting spring ? detector head plugs easily into base ? built-in test switch ? field sensitivity metering of detector to meet the requirements of nfpa 72 ? built-in tamper-resistant feature ? sems screws for easy wiring ? optional recessed mounting the 5451 thermal detector meets the needs for applications where rapid response is vital and rapid temperature increases would only be caused by a fre emergency. this detector contains a unique dual thermistor heat sensing circuit that provides maximum performance and solid-state reliability. it initiates an alarm in response to both rapid rate-of-rise conditions (increases in excess of 15f per minute) and fxed heat (135f). this enables the heat detector to communicate an alarm to the central control panel prior to reaching its fxed set point for high rates of rise, providing a timely response to both rapid and slow temperature increases. additional key features include a recessed mounting option, a variety of mounting bases, and a full line of optional accessories. s2101 ob3ao.ay 7270-1653:104
3825 ohio avenue ? st. charles, il 60174 phone: 800-sensor2 ? fax: 630-377-6495 ?2011 system sensor. product specifcations subject to change without notice. visit systemsensor.com for current product information, including the latest version of this data sheet. a05-0205-009 ? 3/11 ? #2651 accessories ordering information part no. description 5451 fixed heat detector with rate-of-rise. alarm point at 57.2c (135f). must be mounted to one of the 400 series bases listed in mounting base guide. accessories RA100Z remote annunciator for 2- or 4-wire systems, 3 to 32 v. use with ion and photo plug-in detectors. fits standard u.s. single-gang electrical box. mod400r detector sensitivity test tool. (see above.) use with most analog or digital multimeters. satisfes requirement of nfpa 72 for sensitivity testing. (see above.) eolr-1 end of line relay for power supervision, 12/24 vdc, 4-wire only. dust45 replacement protective dust cover for plug-in 400 series. m02-04-01 test magnet. m02-09-00 test magnet with 32-inch telescoping handle. xr5 detector removal tool. allows installation and/or removal of detector heads from base in high-ceiling installations. xp-4 extension pole for xr5. comes in three 5 ft. sections. the mod400r field sensitivity test module can be used with any standard dc voltmeter or multimeter to check the sensitivity range of system sensors detectors (satisfes nfpa 72 requirement for sensitivity testing). wiring 1 2 3 4 (+) (C) (C) (+) (C) 1 2 3 4 (C) (+) (+) eol resistor (+) (C) (C) (+) (C) optional optional ra400z/ RA100Z optional fault tolerant wiring ra400z/ RA100Z b401 400 series plug-in smoke detector specifications physical/operating specifcations size 3.2? (8.1 cm) h; 4.0? (10.2 cm) dia., unfanged base; 6.2? (15.7 cm) dia., fanged base weight 0.3 lb (136 g) operating temperature range 32f to 100f (0c to 38c) humidity range 10% to 93% rh non-condensing construction flame retardant noryl ? plastic alarm point 135f (57.2c) or 15f/min rate-of-rise smoke detector spacing on smooth ceilings (as defned in nfpa 72), spacing of 50 feet (2500 sq ft) may be used. other spacing may be used depending on ceiling height, high air movements, and other conditions or response requirements. standby current 100 a maximum operating voltage/alarm current mounting base dependent (see mounting base selection guide below) mounting base selection guide base model number version loop type current limit resistor alarm contact type nominal voltage current draw on alarm (ma) b401 ? ul/en-54 2-wire* no 12/24 vdc ?? 10 to 100** *functionality contingent on panel compatibility. **must be limited by control panel. ? flangeless base ?? although b401 bases are capable of operating at 12 and 24 vdc, they cannot be used with the 5451 in 12 v applications. junction box selection guide* single gang 3.5 octagon 4 octagon 4 square 50 mm 60 mm 75 mm b401 no no no no yes yes no *box depth contingent on base and wire size. refer to national electrical code of local applicable codes for appropriate recommendations.


▲Up To Search▲   

 
Price & Availability of RA100Z

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X